Division BAT 79: BAT is to monitor emissions to water with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.

United Kingdom

Original text. Later amendments are not shown.

The minimum monitoring frequency may be reduced to once every month if adequate performance of the solids and copper removal is controlled by frequent monitoring of other parameters (e.g. by continuous measurement of turbidity).

Substance/ParameterPlantSampling pointStandard(s)Minimum monitoring frequencyMonitoring associated with
EDCAll plantsOutlet of the waste water stripperEN ISO 10301Once every dayBAT 80
VCM
CopperOxy-chlorination plant using the fluidised-bed designOutlet of the pretreatment for solids removalVarious EN standards available, e.g. EN ISO 11885, EN ISO 15586, EN ISO 17294-2Once every dayf1 BAT 81
PCDD/FNo EN standard availableOnce every 3 months
Total suspended solids (TSS)EN 872Once every day
CopperOxy-chlorination plant using the fluidised-bed designOutlet of the final waste water treatmentVarious EN standards available, e.g. EN ISO 11885, EN ISO 15586, EN ISO 17294-2Once every monthBAT 14 and BAT 81
EDCAll plantsEN ISO 10301Once every monthBAT 14 and BAT 80
PCDD/FNo EN standard availableOnce every 3 monthsBAT 14 and BAT 81

Annotations

Footnotes

f1

The minimum monitoring frequency may be reduced to once every month if adequate performance of the solids and copper removal is controlled by frequent monitoring of other parameters (e.g. by continuous measurement of turbidity).