Division BAT 82: In order to use energy efficiently, BAT is to use a boiling reactor for the direct chlorination of ethylene.
United Kingdom
Description:
The reaction in the boiling reactor system for the direct chlorination of ethylene is typically carried out at a temperature between below 85 °C and 200 °C. In contrast to the low-temperature process, it allows for the effective recovery and reuse of the heat of reaction (e.g. for the distillation of EDC).
Applicability:
Only applicable to new direct chlorination plants.