OpenLegislation

Division BAT 84: In order to reduce the amount of coke being sent for disposal from VCM plants, BAT is to use a combination of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescriptionApplicability
a.Use of promoters in crackingSee BAT 83Generally applicable
b.Rapid quenching of the gaseous stream from EDC crackingThe gaseous stream from EDC cracking is quenched by direct contact with cold EDC in a tower to reduce coke formation. In some cases, the stream is cooled by heat exchange with cold liquid EDC feed prior to quenchingGenerally applicable
c.Pre-evaporation of EDC feedCoke formation is reduced by evaporating EDC upstream of the reactor to remove high-boiling coke precursorsOnly applicable to new plants or major plant upgrades
d.Flat flame burnersA type of burner in the furnace that reduces hot spots on the walls of the cracker tubesOnly applicable to new furnaces or major plant upgrades