OpenLegislation

Division 2.1.1 BAT-AELs for emissions to air from a lower olefins cracker furnace

United Kingdom

Original text. Later amendments are not shown.

Table 2.1

BAT-AELs for emissions to air of NOX and NH3 from a lower olefins cracker furnace

Where the flue gases of two or more furnaces are discharged through a common stack, the BAT-AEL applies to the combined discharge from the stack.

The BAT-AELs do not apply during decoking operations.

No BAT-AEL applies for CO. As an indication, the CO emission level will generally be 10–50 mg/Nm3 expressed as a daily average or an average over the sampling period.

The BAT-AEL only applies when SCR or SNCR are used.

ParameterBAT-AELsf1 f2 f3(daily average or average over the sampling period)(mg/Nm3, at 3 vol-% O2)
New furnaceExisting furnace
NOX 60–10070–200
NH3 < 5–15f4

The associated monitoring is in BAT 1.

Annotations

Footnotes

f1

Where the flue gases of two or more furnaces are discharged through a common stack, the BAT-AEL applies to the combined discharge from the stack.

f2

The BAT-AELs do not apply during decoking operations.

f3

No BAT-AEL applies for CO. As an indication, the CO emission level will generally be 10–50 mg/Nm3 expressed as a daily average or an average over the sampling period.

f4

The BAT-AEL only applies when SCR or SNCR are used.