Division BAT 68: BAT is to monitor emissions to water with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.

United Kingdom

Original text. Later amendments are not shown.

In the case of discontinuous waste water discharges, the minimum monitoring frequency is once per discharge.

Substance/ParameterPlantSampling pointStandard(s)Minimum monitoring frequencyMonitoring associated with
TOCDNT plantOutlet of the pretreatment unitEN 1484Once every weekf1 BAT 70
MDI and/or TDI plantOutlet of the plantOnce every monthBAT 72
AnilineMDA plantOutlet of the final waste water treatmentNo EN standard availableOnce every monthBAT 14
Chlorinated solventsMDI and/or TDI plantVarious EN standards available (e.g. EN ISO 15680)BAT 14

Annotations

Footnotes

f1

In the case of discontinuous waste water discharges, the minimum monitoring frequency is once per discharge.