In order to prevent emissions to soil and water from slurry collection, piping, and from a store and/or an earth-banked storage (lagoon), BAT is to use a combination of the techniques given below.

A description of the techniques is given in Section 3.1.1 and 4.6.2.

Techniquef1 Applicability
aUse stores that are able to withstand mechanical, chemical and thermal influences.Generally applicable.
bSelect a storage facility with a sufficient capacity to hold the slurry during periods in which landspreading is not possible.Generally applicable.
cConstruct leak-proof facilities and equipment for collection and transfer of slurry (e.g. pits, channels, drains, pump stations).Generally applicable.
dStore slurry in earth-banked stores (lagoons) with an impermeable base and walls e.g. with clay or plastic lining (or double-lined).Generally applicable to lagoons.
eInstall a leakage detection system, e.g. consisting of a geomembrane, a drainage layer and a drainage pipe system.Only applicable to new plants.
fCheck structural integrity of stores at least once every year.Generally applicable.

Annotations

Footnotes

f1