For each efficient exterior LED light included in the combination the measurement of the current shall be performed as shown in the Figure at a voltage of 13,2 V. LED module(s) operated by an electronic light source control gear, shall be measured as specified by the applicant.

The manufacturer may request that other measurements of the current shall be done at other additional voltages. In that case, the manufacturer shall hand over verified documentation on the necessity to perform those other measurements to the type-approval authority. The measurements of the currents at each of those additional voltages shall be performed consecutively at least five times. The exact installed voltages and the measured current shall be recorded in four decimals.

The power consumption shall be determined by multiplying the installed voltage with the measured current. The average of the power consumption for each efficient exterior LED light ( P EI i – ) shall be calculated. Each value shall be expressed in four decimals. When a stepper motor or electronic controller is used for the supply of the electricity to the LED lights, the electric load of that component part shall be excluded from the measurement.

Notes on Division 3

Footnotes

f1

OJ L 4, 7.1.2012, p. 17.

f2

OJ L 213, 18.7.2014, p. 1.

f3

OJ L 285, 30.9.2014, p. 1.

f4

OJ L 250, 22.8.2014, p. 1.

f5

OJ L 237, 8.8.2014, p. 1.

f6

OJ L 148, 12.6.2010, p. 55.

f7

OJ L 323, 6.12.2011, p. 46.

f8

OJ L 302, 28.11.2018, p. 114.

f9

OJ L 250, 22.8.2014, p. 67.

f10

OJ L 89, 25.3.2014, p. 101.

f11

OJ L 222, 24.8.2010, p. 1.