OpenLegislation

Division 1.2 Monitoring

United Kingdom

Original text. Later amendments are not shown.

BAT 3. For relevant emissions to water as identified by the inventory of waste water streams (see BAT 2), BAT is to monitor key process parameters (e.g. continuous monitoring of waste water flow, pH and temperature) at key locations (e.g. at the inlet and/or outlet of the pre-treatment, at the inlet to the final treatment, at the point where the emission leaves the installation).

BAT 4. BAT is to monitor emissions to water with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.

The monitoring only applies when the substance concerned is identified as relevant in the waste water stream based on the inventory mentioned in BAT 2.

The monitoring only applies in the case of a direct discharge to a receiving water body.

TOC monitoring and COD monitoring are alternatives. TOC monitoring is the preferred option because it does not rely on the use of very toxic compounds.

If the emission levels are proven to be sufficiently stable, a lower monitoring frequency can be adopted but in any case at least once every month.

Substance/parameterStandard(s)Minimum monitoring frequency f1 Monitoring associated with
Chemical oxygen demand (COD) f2 f3 No EN standard availableOnce every day f4 BAT 12
Total nitrogen (TN) Various EN standards available (e.g. EN 12260, EN ISO 11905-1)
Total organic carbon (TOC) EN 1484
Total phosphorus (TP) Various EN standards available (e.g. EN ISO 6878, EN ISO 15681-1 and -2, EN ISO 11885)
Total suspended solids (TSS) EN 872
Biochemical oxygen demand (BODn) EN 1899-1Once every month
Chloride (Cl-)Various EN standards available (e.g. EN ISO 10304-1, EN ISO 15682)Once every month—

BAT 5. BAT is to monitor channelled emissions to air with at least the frequency given below and in accordance with EN standards.

The measurements are carried out at the highest expected emission state under normal operating conditions.

If the emission levels are proven to be sufficiently stable, a lower monitoring frequency can be adopted but in any case at least once every year.

The measurement is carried out during a campaign of two days.

The monitoring only applies when a thermal oxidiser is used.

Substance/ParameterSectorSpecific processStandard(s)Minimum monitoring frequency f5 Monitoring associated with
DustAnimal feedDrying of green fodderEN 13284-1Once every three months f6 BAT 17
Grinding and pellet cooling in compound feed manufactureOnce every yearBAT 17
Extrusion of dry pet foodOnce every yearBAT 17
BrewingHandling and processing of malt and adjunctsOnce every yearBAT 20
DairiesDrying processesOnce every yearBAT 23
Grain millingGrain cleaning and millingOnce every yearBAT 28
Oilseed processing and vegetable oil refiningHandling and preparation of seeds, drying and cooling of mealOnce every yearBAT 31
Starch productionDrying of starch, protein and fibreBAT 34
Sugar manufacturingDrying of beet pulpOnce every month BAT 36
PM2.5 and PM10 Sugar manufacturingDrying of beet pulpEN ISO 23210Once every yearBAT 36
TVOCFish and shellfish processingSmoke chambersEN 12619Once every yearBAT 26
Meat processingSmoke chambersBAT 29
Oilseed processing and vegetable oil refining f7 ——
Sugar manufacturingHigh-temperature drying of beet pulpOnce every year—
NOX Meat processing f8 Smoke chambersEN 14792Once every year—
Sugar manufacturingHigh-temperature drying of beet pulp
COMeat processing Smoke chambersEN 15058
Sugar manufacturingHigh-temperature drying of beet pulp
SOX Sugar manufacturingDrying of beet pulp when natural gas is not usedEN 14791Twice every year BAT 37

Annotations

Footnotes

f1

The monitoring only applies when the substance concerned is identified as relevant in the waste water stream based on the inventory mentioned in BAT 2.

f2

The monitoring only applies in the case of a direct discharge to a receiving water body.

f3

TOC monitoring and COD monitoring are alternatives. TOC monitoring is the preferred option because it does not rely on the use of very toxic compounds.

f4

If the emission levels are proven to be sufficiently stable, a lower monitoring frequency can be adopted but in any case at least once every month.

f5

The measurements are carried out at the highest expected emission state under normal operating conditions.

f6

If the emission levels are proven to be sufficiently stable, a lower monitoring frequency can be adopted but in any case at least once every year.

f7

The measurement is carried out during a campaign of two days.

f8

The monitoring only applies when a thermal oxidiser is used.