Division BAT 10 BAT is to monitor total and fugitive VOC emissions by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7(2) of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below.
United Kingdom
| Technique | Description | |
|---|---|---|
| (a) | Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty | This includes:
|
| (b) | Implementation of a solvent tracking system | A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area). |
| (c) | Monitoring of changes that may influence the uncertainty of the solvent mass balance data | Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as:
|
Applicability
The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the installation, and the range of environmental impacts it may have, as well as to the type and quantity of materials used.