Division Note:F1
United Kingdom
Preliminary testing with this method should permit reproducible detection of 10 3 to 10 4 cells of C. m. subsp. sepedonicus per ml added to sample extracts which previously tested negative. Optimisation experiments may be required to achieve maximum levels of sensitivity and specificity in all laboratories.
Use validated PCR reagents and protocols. Preferably select a method with an internal control.
Use appropriate precautions to avoid contamination of sample with target DNA. The PCR test should be performed by experienced technicians, in dedicated molecular biology laboratories, in order to minimise the possibility of contamination with target DNA.