OpenLegislation

Division 3 REPORTING

United Kingdom

Original text. Later amendments are not shown.

The test report must include the following information:

Complete identification of the soil used including:

  • geographical reference of the site (latitude, longitude);

  • information on the history of the site (i.e. vegetation cover, treatments with crop protection products, treatments with fertilisers, accidental contamination, etc.);

  • use pattern (e.g. agricultural soil, forest, etc.);

  • depth of sampling (cm);

  • sand/silt/clay content (% dry weight);

  • pH (in water);

  • organic carbon content (% dry weight);

  • nitrogen content (% dry weight);

  • initial nitrate concentration (mg nitrate/kg dry weight);

  • cation exchange capacity (mmol/kg);

  • micfobial biomass in terms of percentage of the total organic carbon;

  • reference of the methods used for the determination of each parameter;

  • all information relating to the collection and storage of soil samples;

  • details of pre-incubation of soil if any.

Test substance:

  • physical nature and, where relevant, physical-chemical properties;

  • chemical identification data, where relevant, including structural formula, purity (i.e. for crop protection products the percentage of active ingredient), nitrogen content.

Substrate:

  • source of substrate;

  • composition (i.e. lucerne meal, lucerne-grass-green meal);

  • carbon, nitrogen content (% dry weight);

  • sieve size (mm).

Test conditions:

  • details of the amendment of soil with organic substrate;

  • number of concentrations of test chemical used and, where appropriate, justification of the selected concentrations;

  • details of the application of test substance to soil;

  • incubation temperature;

  • soil moisture content at the beginning and during the test;

  • method of soil incubation used (i.e. as bulk or as a series of individual subsamples);

  • number of replicates;

  • sampling times;

  • method used for extraction of nitrate from soil;

Results:

  • analytical procedure and equipment used to analyse nitrate;

  • tabulated data including individual and mean values for nitrate measurements;

  • variation between the replicates in treated and control samples;

  • explanations of corrections made in the calculations, if relevant;

  • the percent variation in nitrate formation rates at each sampling time or, if appropriate, the EC50 value with 95 per cent confidence limit, other ECx (i.e. EC25 or EC10) with confidence intervals, and a graph of the dose-response curve;

  • statistical treatment of results;

  • all information and observations helpful for the interpretation of the results.