Division .3 Fixed fire-extinguishing systemF1
United Kingdom
Each special category space shall be fitted with an approved fixed pressure water-spraying system for manual operation which shall protect all parts of any deck and vehicle platform in such space.
In new class B, C and D ships constructed on or after 1 January 2003 , such water spray systems shall have:
- .1
a pressure gauge on the valve manifold;
- .2
clear marking on each manifold valve indicating the spaces served;
- .3
instructions for maintenance and operation located in the valve room; and
- .4
a sufficient number of drainage valves.
The Administration of the flag State may permit the use of any other fixed fire-extinguishing system that has been shown by full-scale test in conditions simulating a flowing petrol fire in a special category space to be not less effective in controlling fires likely to occur in such a space. Such fixed pressure water-spraying system or other equivalent fire-extinguishing system shall comply with the provisions of IMO Resolution A.123(V) and the IMO MSC/Circ.1272 ‘ Guidelines when approving alternative water-based fire-fighting systems for use in special category spaces ’ shall be taken into consideration.