Ventilation ducts shall be constructed of the following materials:

  1. .1

    ducts not less than 0,075 m 2 in sectional area and all vertical ducts serving more than a single between-deck space shall be constructed of steel or other equivalent material;

  2. .2

    ducts less than 0,075 m 2 in sectional area other than vertical ducts referred to in subparagraph .1.4.1 shall be constructed of non-combustible materials. Where such ducts penetrate ‘A’ or ‘B’ class divisions due regard shall be given to ensuring the fire integrity of the division;

  3. .3

    short lengths of duct, not in general exceeding 0,02 m 2 in sectional area nor two metres in length, need not be non-combustible provided that all of the following conditions are met:

    1. .1

      the duct is constructed of a material of low fire risk to the satisfaction of the Administration of the flag State;

    2. .2

      the duct is used only at the terminal end of the ventilation system; and

    3. .3

      the duct is not located closer than 600 mm measured along its length to a penetration of an ‘ A ’ or ‘ B ’ class division, including continuous ‘ B ’ class ceilings.

  1. CLASS B, C AND D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2003 :

Annotations

Textual amendments

F1

Substituted by Commission Directive 2010/36/EU of 1 June 2010 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (Text with EEA relevance).

Notes on Division 9

Textual amendments

F2

Substituted by Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (Text with EEA relevance).