Division 7.1.1 The effect of an electromagnetic disturbance on a water meter shall be such that:
United Kingdom
-
the change in the measurement result is no greater than the critical change value as defined in point 7.1.3, or
-
the indication of the measurement result is such that it cannot be interpreted as a valid result, such as a momentary variation that cannot be interpreted, memorised or transmitted as a measuring result.