OpenLegislation

Division 1 Rated operating conditions

United Kingdom

Original text. Later amendments are not shown.

The values of the rated operating conditions shall be specified by the manufacturer as follows:

  1. 1.1.

    For the temperature of the liquid: θmax, θmin,

    • for the temperature differences: Δθmax, Δθmin,

    subject to the following restrictions: Δθ max ∕ Δθ min ≥ 10 ; Δθmin = 3 K or 5 K or 10 K.

  2. 1.2.

    For the pressure of the liquid: The maximum positive internal pressure that the thermal energy meter can withstand permanently at the upper limit of the temperature.

  3. 1.3.

    For the flow rates of the liquid: qs, qp, qi, where the values of qp and qi are subject to the following restriction: q p ∕ q i ≥ 10 .

  4. 1.4.

    For the thermal power: Ps.