The relative MPE of the flow sensor, expressed in %, for accuracy classes:

  • Class 1: E f = 1 + 0,01 q p ∕ q , but not more than 5 %,

  • Class 2: E f = 2 + 0,02 q p ∕ q , but not more than 5 %,

  • Class 3: E f = 3 + 0,05 q p ∕ q , but not more than 5 %,

where the error Ef relates the indicated value to the true value of the relationship between flow sensor output signal and the mass or the volume.