Associated measuring instruments shall have an accuracy at least as good as the values in Table 4:

Table 4

MPE on MeasurementsAccuracy classes of the measuring system
0,30,51,01,52,5
Temperature± 0,3 °C± 0,5 °C± 1,0 °C
Pressure

Less than 1 MPa: ± 50 kPa

From 1 to 4 MPa: ± 5 %

Over 4 MPa: ± 200 kPa

Density± 1 kg/m3 ± 2 kg/m3 ± 5 kg/m3

These values apply to the indication of the characteristic quantities of the liquid displayed by the conversion device.