Division (3) Annex V to Directive 2000/54/EC is replaced by the following:

United Kingdom

Original text. Later amendments are not shown.

‘ANNEX V

INDICATIONS CONCERNING CONTAINMENT MEASURES AND CONTAINMENT LEVELS

(Articles 15(3) and 16(1)(a) and (b))

Preliminary note

The measures contained in this Annex shall be applied according to the nature of the activities, the assessment of risk to workers, and the nature of the biological agent concerned.

In the table, “Recommended” means that the measures should in principle be applied, unless the results of the assessment referred to in Article 3(2) indicate otherwise.

HEPA: High efficiency particulate air

Airlock: Entry must be through an airlock which is a chamber isolated from the laboratory. The clean side of the airlock must be separated from the restricted side by changing or showering facilities and preferably by interlocking doors.

A. Containment measuresB. Containment levels
234
Workplace
1. The workplace is to be separated from any other activities in the same buildingNoRecommendedYes
2. The workplace is to be sealable to permit fumigationNoRecommendedYes
Facilities
3. Infected material including any animal is to be handled in a safety cabinet or isolation or other suitable containmentWhere appropriateYes, where infection is by airborne routeYes
Equipment
4. Input air and extract air to the workplace are to be filtered using (HEPAf1) or likewiseNoYes, on extract airYes, on input and extract air
5. The workplace is to be maintained at an air pressure negative to atmosphereNoRecommendedYes
6. Surfaces impervious to water and easy to cleanYes, for bench and floorYes, for bench, floor and other surfaces determined by risk assessmentYes, for bench, walls, floor and ceiling
7. Surfaces resistant to acids, alkalis, solvents, disinfectantsRecommendedYesYes
System of work
8. Access is to be restricted to nominated workers onlyRecommendedYesYes, via airlockf2
9. Efficient vector control, for example rodents and insectsRecommendedYesYes
10. Specified disinfection proceduresYesYesYes
11. Safe storage of a biological agentYesYesYes, secure storage
12. Personnel should shower before leaving the contained areaNoRecommendedRecommended
Waste
13. Validated inactivation process for the safe disposal of animal carcasesRecommendedYes, on or off siteYes, on site
Other measures
14. A laboratory is to contain its own equipmentNoRecommendedYes
15. An observation window, or, alternative, is to be present, so that occupants can be seenRecommendedRecommendedYes

’

Annotations

Footnotes

f1

HEPA: High efficiency particulate air

f2

Airlock: Entry must be through an airlock which is a chamber isolated from the laboratory. The clean side of the airlock must be separated from the restricted side by changing or showering facilities and preferably by interlocking doors.