OpenLegislation

Appendix A F1

United Kingdom

Original text. Later amendments are not shown.

Determination of linear gas speed

Inject 1:3 μl of methane (or propane) into the gas chromatograph after adjusting it to the normal operating conditions. Measure the time the gas takes to run through the column from the moment it is injected until the peak emerges (tM).

The linear speed in cm/s is given by L/tM where L is the length of the column, in cm, and tM is the time measured in s.

Annotations

Textual amendments

F1

Inserted by Commission Regulation (EU) No 61/2011 of 24 January 2011 amending Regulation (EEC) No 2568/91 on the characteristics of olive oil and olive-residue oil and on the relevant methods of analysis.

Notes on Annex XX

Footnotes

f1

After elution of the sterol esters, the chromatogram should not show any significant peaks (triacylglycerols).