OpenLegislation

Division

United Kingdom

Original text. Later amendments are not shown.

F1Note: The statement on the calculated false suspected rate indicates if the method is fit-for-purpose as it indicates the number of blank (or low level contamination) samples that will be subject to verification.

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) No 519/2014 of 16 May 2014 amending Regulation (EC) No 401/2006 as regards methods of sampling of large lots, spices and food supplements, performance criteria for T-2, HT-2 toxin and citrinin and screening methods of analysis (Text with EEA relevance).

Notes on Division 4.3.2.8

Footnotes

f1

If a buffer is used to stabilise the pH changes in the extraction step, then this commodity group can be merged into one commodity group ‘ High water content ’ .

f2

‘ Difficult or unique commodities ’ should only be fully validated if they are frequently analysed. If they are only analysed occasionally, validation may be reduced to just checking the reporting levels using spiked blank extracts.