The exhaust gases mentioned in paragraph 4.3.1.1 shall be understood as including methane, water and hydrogen:

‘ … (HFID). It shall be calibrated with propane gas expressed as equivalent to carbon atoms (C 1 ).

Methane (CH 4 ) analysis:

The analyser shall be either a gas chromatograph combined with a flame ionisation (FID) type or a flame ionisation (FID) with a non-methane cutter type, calibrated with methane gas expressed as equivalent to carbon atoms (C 1 ).

Water (H 2 O) analysis:

The analyser shall be of the non-dispersive infrared analyzer (NDIR) absorption type. The NDIR shall be calibrated either with water vapour or with propylene (C 3 H 6 ). If the NDIR is calibrated with water vapour, it shall be ensured that no water condensation can occur in tubes and connections during the calibration process. If the NDIR is calibrated with propylene, the manufacturer of the analyzer shall provide the information for converting the concentration of propylene to its corresponding concentration of water vapour. The values for conversion shall be periodically checked by the manufacturer of the analyzer, and at least once per year.

Hydrogen (H 2 ) analysis:

The analyser shall be of the sector field mass spectrometry type, calibrated with hydrogen.

Nitrogen oxide (NO x ) … ’ .

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) No 630/2012 of 12 July 2012 amending Regulation (EC) No 692/2008, as regards type-approval requirements for motor vehicles fuelled by hydrogen and mixtures of hydrogen and natural gas with respect to emissions, and the inclusion of specific information regarding vehicles fitted with an electric power train in the information document for the purpose of EC type-approval (Text with EEA relevance).