Division 5.1.2 Canister vibration conditioning testF1
United Kingdom
After the temperature aging procedure, the canister(s) is (are) shaken along the vertical axis with the canister(s) mounted as per its orientation in the vehicle with overall Grms f1 > 1,5 m/sec 2 with frequency of 30 ± 10 Hz. The test shall last 12 hours.
Annotations
Textual amendments
Footnotes
- f1
- Grms
The root mean square (rms) value of the vibration signal is calculated by squaring the magnitude of the signal at every point, finding the average (mean) value of the squared magnitude, then taking the square root of the average value. The resulting number is the Grms metric.