After the temperature conditioning test and vibration test, the canister(s) is aged with a mixture of Type I E10 market fuel as specified in point 5.1.3.1.1.1 below and nitrogen or air with a 50 ± 15 percent fuel vapour volume. The fuel vapour fill rate must be kept between 60 ± 20 g/h.

The canister(s) is (are) loaded to the corresponding breakthrough. Breakthrough shall be considered as the point at which the cumulative quantity of hydrocarbons emitted is equal to 2 grams. As an alternative, the loading is deemed completed when the equivalent concentration level at the vent hole reaches 3 000 ppm.

  1. 5.1.3.1.1.1Division 5.1.3.1.1.1

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) 2017/1221 of 22 June 2017 amending Regulation (EC) No 692/2008 as regards the methodology for the determination of evaporative emissions (Type 4 test) (Text with EEA relevance).