OpenLegislation

Division 3.2.12.2.7.6.4

United Kingdom

Original text. Later amendments are not shown.

The information required by this section may, be defined by completing a table as follows,

ComponentFault codeMonitoring strategyFault detection criteriaMI activation criteriaSecondary parametersPreconditioningDemonstration test
CatalystPO420Oxygen sensor 1 and 2 signalsDifference between sensor 1 and sensor 2 signals3rd cycleEngine speed, engine load, A/F mode, catalyst temperatureTwo Type 1 cyclesType 1