Division [3A] Systems, Equipment and ComponentsF1
United Kingdom
Note 1:The control status of equipment and components described in 3A001 or 3A002, other than those described in 3A001.a.3. to 3A001.a.10., F23A001.a.12. to 3A001.a.14., F33A001.b.12. or 3A501.a.15. which are specially designed for or which have the same functional characteristics as other equipment is determined by the control status of the other equipment.
Note 2:The control status of integrated circuits described in 3A001.a.3. to 3A001.a.9., or 3A001.a.12. to 3A001.a.14., which are unalterably programmed or designed for a specific function for another equipment is determined by the control status of the other equipment.
NB:When the manufacturer or applicant cannot determine the control status of the other equipment, the control status of the integrated circuits is determined in 3A001.a.3. to 3A001.a.9., and 3A001.a.12. to 3A001.a.14.
Note 3:The status of wafers (finished or unfinished), in which the function has been determined, is to be evaluated against the parameters of 3A001.a., 3A001.b., 3A001.d., 3A001.e.4., 3A001.g., 3A001.h., or 3A001.i.
- [3A001]Electronic items as follows:
- [3A002]General purpose "electronic assemblies", modules and equipment, as follows:
- [3A003]Spray cooling thermal management systems employing closed loop fluid handling and reconditioning equipment in a sealed enclosure where a dielectric fluid is sprayed onto electronic components using specially designed spray nozzles that are designed to maintain electronic components within their operating temperature range, and specially designed components therefor.
- [3A101]Electronic equipment, devices and components, other than those specified in 3A001, as follows:
- [3A102]‘Thermal batteries’ designed or modified for ‘missiles’.
- [3A201]Electronic components, other than those specified in 3A001, as follows;
- [3A225]Frequency changers or generators, other than those specified in 0B001.b.13., usable as a variable or fixed frequency motor drive, having all of the following characteristics:
- [3A226]High-power direct current power supplies, other than those specified in 0B001.j.6., having both of the following characteristics:
- [3A227]High-voltage direct current power supplies, other than those specified in 0B001.j.5., having both of the following characteristics:
- [3A228]Switching devices, as follows:
- [3A229]High-current pulse generators as follows:
- [3A230]High-speed pulse generators, and ‘pulse heads’ therefor, having both of the following characteristics:
- [3A231]Neutron generator systems, including tubes, having both of the following characteristics:
- [3A232]Multipoint initiation systems, other than those specified in 1A007, as follows:
- [3A233]Mass spectrometers, other than those specified in 0B002.g., capable of measuring ions of 230 u or greater and having a resolution of better than 2 parts in 230, as follows, and ion sources therefor:
- [3A234]Striplines to provide low inductance path to detonators with the following characteristics:
- [3A501]Electronic items, as follows:
- [3A502]General purpose “electronic assemblies”, modules and equipment, as follows:
- [3A504]Cryogenic cooling systems and components, as follows:
Annotations
Textual amendments
- F1
- F2
Words in Annex 1 substituted (31.3.2023) by The Export Control (Military and Dual-Use Lists) (Amendment) Regulations 2023 (S.I. 2023/302), regs. 1, 5(2)(d)(i)
- F3
Words in Annex 1 Section 3A Note 1 substituted (16.12.2025) by The Export Control (Amendment) (No. 2) Regulations 2025 (S.I. 2025/1197), regs. 1(2), 9(2)(a)