Division
United Kingdom
Accuracy of pedal force and disc temperature measurements shall be as follows:
| Applicable as specified in point 7.2.5. | ||
| Measurement | Typical operating range of the transducers | Recommended maximum recording errors |
|---|---|---|
| Pedal force | 0 to 2 000 N | ±10 N |
| Brake disc temperature | 0-1 000 °C | ±5 °C |
| Brake Pressuref1 | 0-20 MPa | ±100 kPa |
Annotations
Footnotes
- f1
-
Applicable as specified in point 7.2.5.