Division 1.5.6.3 Procedure
United Kingdom
The test substance is applied to the surface of a roughened glass plate as a homogeneous layer. In the case of solids, the plate is wetted uniformly by a solution of the substance in a suitable solvent and dried in an inert atmosphere. For the measurement, the coated plate is hung into the thermogravimetric analyser and subsequently its weight loss is measured continuously as a function of time.
The evaporation rate vT at a definite temperature is calculated from the weight loss Δm of the sample plate by
where F is the surface area of the coated test substances, normally the surface area of the sample plate, and t is the time for weight loss Δm.
The vapour pressure pT is calculated on the basis of its function of evaporation rate vT:
Log pT = C + D · log vT
where C and D are constants specific for the experimental arrangement used, depending on the diameter of the measurement chamber and on the gas flow rate. These constants must be determined once by measuring a set of compounds with known vapour pressure and regressing log pT vs. log vT (11)(21)(22).
The relationship between the vapour pressure pT and the temperature T in Kelvin is given by
Log pT = A + B · 1/T
where A and B are constants obtained by regressing log pT vs. 1/T. With this equation, the vapour pressure can be calculated for any other temperature by extrapolation.