Division 3.1 TEST REPORT
United Kingdom
The test report should include the following information:
Test and Control Substances:
-
chemical name(s) such as IUPAC or CAS name and CAS number, if known,
-
purity and composition of the substance (in percentage(s) by weight),
-
physical-chemical properties relevant to the conduct of the study (e.g. physical state, stability and volatility, pH, water solubility if known),
-
treatment of the test/control substances prior to testing, if applicable (e.g. warming, grinding),
-
storage conditions.
Justification of the skin model and protocol used.
Test Conditions:
-
cell system used,
-
calibration information for measuring device, and bandpass used for measuring cell viability (e.g. spectrophotometer),
-
complete supporting information for the specific skin model used including its performance. This should include, but is not limited to:
- (i)
viability;
- (ii)
barrier function;
- (iii)
morphology;
- (iv)
reproducibility and predictivity;
- (v)
quality controls (QC) of the model;
- (i)
-
details of the test procedure used,
-
test doses used, duration of exposure and post treatment incubation period,
-
description of any modifications of the test procedure,
-
reference to historical data of the model. This should include, but is not limited to:
- (i)
acceptability of the QC data with reference to historical batch data;
- (ii)
acceptability of the positive and negative control values with reference to positive and negative control means and ranges,
- (i)
-
description of evaluation criteria used including the justification for the selection of the cut-off point(s) for the prediction model.
Results:
-
tabulation of data from individual test samples,
-
description of other effects observed.
Discussion of the results.