Division 3.1 TEST REPORT
United Kingdom
The test report must include the following:
Test substance:
-
physical nature and physicochemical properties, including water solubility limit,
-
chemical identification data (e.g. CAS Number), including purity.
Test species:
-
scientific name, clone (if known) and source.
Test conditions:
-
test procedure used (static, semi-static or flow-through),
-
date of start of the test and its duration,
-
test medium,
-
description of the experimental design: test vessels and covers, solution volumes, number of colonies and fronds per test vessel at the beginning of the test,
-
test concentrations (nominal and measured as appropriate) and number of replicates per concentration,
-
methods of preparation of stock and test solutions including the use of any solvents or dispersants,
-
temperature during the test,
-
light source, light intensity and homogeneity,
-
pH values of the test and control media,
-
test substance concentrations and the method of analysis with appropriate quality assessment data (validation studies, standard deviations or confidence limits of analyses),
-
methods for determination of frond number and other measurement variables, e.g. dry weight, fresh weight or frond area,
-
all deviations from this Testing Method.
Results:
-
raw data: number of fronds and other measurement variables in each test and control vessel at each observation and occasion of analysis,
-
means and standard deviations for each measurement variable,
-
growth curves for each concentration (recommended with log transformed measurement variable, see second paragraph in section 2.2.1),
-
doubling time/growth rate in the control based on the frond number,
-
calculated response variables for each treatment replicate, with mean values and coefficient of variation for replicates,
-
graphical representation of the concentration/effect relationship,
-
estimates of toxic endpoints for response variables e.g. EC50, EC10, EC20, and associated confidence intervals. If calculated, LOEC and/or NOEC and the statistical methods used for their determination,
-
if ANOVA has been used, the size of the effect which can be detected (e.g. the least significant difference),
-
any stimulation of growth found in any treatment,
-
any visual signs of phytotoxicity as well as observations of test solutions,
-
discussion of the results, including any influence on the outcome of the test resulting from deviations from this Testing Method.