The tank shall be filled with water. The pressure shall be increased at a constant rate not exceeding 0,5 MPa/min until burst. When the Maximum Allowable Working Pressure (MAWP) is reached there shall be a wait period of at least ten minutes at constant pressure so that the deformation of the tank shall be checked.