Division 2.7.5.1 Material temperatures
The normal operating temperature range for materials used in hydrogen components shall be – 40 °C to + 85 °C except if:
- (a)
the vehicle manufacturer specifies a lower temperature than – 40 °C;
- (b)
hydrogen components are situated either in an internal combustion engine compartment or directly exposed to the operating temperature of an internal combustion engine, for which the temperature range shall be – 40 °C to + 120 °C.