Special consideration shall be given to safety when conducting this test.

At ambient temperature use hydrogen to pressure cycle for 3,0 times the number of filling cycles in accordance with section 2.7.6., either:

  1. (a)

    The container between ≤ 2,0 MPa and ≥ 1,25 times the nominal working pressure, or;

  2. (b)

    The liner between the pressure levels that shall provide an equivalent liner wall stress as would be present at ≤ 2,0 MPa and ≥ 1,25 times the nominal working pressure for the container.