Division 4.2.2.2 Procedure
Pressure cycling shall be performed at ambient temperature in accordance with the following procedure:
- (a)
Fill the container to be tested with a non-corrosive fluid such as oil, inhibited water or glycol;
- (b)
Pressure cycle for 3,0 times the number of filling cycles in accordance with section 2.7.6., from ≤ 2,0 MPa to ≥ 1,25 times nominal working pressure at a rate not exceeding 10 cycles per minute.
For type-approval, containers shall be cycled until failure occurs or up to 9 times the number of filling cycles.
For batch testing, the requirements of section 3.9.1. shall be followed.