The results shall be presented in a test summary, as specified in the addendum to the F1GB type-approval certificate as set out in Part 2 to Annex II, and shall include at least the following data for each container:

  1. (a)

    The elapsed time from ignition of the fire to the start of venting through the pressure relief device(s);

  2. (b)

    The maximum pressure and time of evacuation until a pressure ≤ 1,0 MPa is reached.