Division 4.2.9.2 Procedure
The containers, with the composite wrapping free of any protective coating, shall be hydrostatically cycle tested in the following sequence:
- (a)
Condition for 48 hours with a temperature ≥ 85 °C and a relative humidity ≥ 95 per cent;
- (b)
Pressure cycle between ≤ 2,0 MPa and ≥ 1,25 times nominal working pressure at a temperature ≥ 85 °C and a relative humidity ≥ 95 per cent, for 1,5 times the number of filling cycles calculated in accordance with section 2.7.6.;
- (c)
Stabilise at ambient conditions;
- (d)
Condition the container and test fluid to a temperature ≤ – 40 °C as measured on the container surface and in the fluid;
- (e)
Pressure cycle at ≤ – 40 °C between ≤ 2,0 MPa and ≥ nominal working pressure, for 1,5 times the number of filling cycles calculated in accordance with section 2.7.6.;
- (f)
Leak testf1 in accordance with section 4.2.11.;
- (g)
Burst test in accordance with section 4.2.1.2.
Annotations
Footnotes
- f1
-
Applies to type 4 containers and type 3 with welded metal liners.