Division 4.2.9.2 Procedure

Original text. Later amendments are not shown.

The containers, with the composite wrapping free of any protective coating, shall be hydrostatically cycle tested in the following sequence:

  1. (a)

    Condition for 48 hours with a temperature ≥ 85 °C and a relative humidity ≥ 95 per cent;

  2. (b)

    Pressure cycle between ≤ 2,0 MPa and ≥ 1,25 times nominal working pressure at a temperature ≥ 85 °C and a relative humidity ≥ 95 per cent, for 1,5 times the number of filling cycles calculated in accordance with section 2.7.6.;

  3. (c)

    Stabilise at ambient conditions;

  4. (d)

    Condition the container and test fluid to a temperature ≤ – 40 °C as measured on the container surface and in the fluid;

  5. (e)

    Pressure cycle at ≤ – 40 °C between ≤ 2,0 MPa and ≥ nominal working pressure, for 1,5 times the number of filling cycles calculated in accordance with section 2.7.6.;

  6. (f)

    Leak testf1 in accordance with section 4.2.11.;

  7. (g)

    Burst test in accordance with section 4.2.1.2.

  1. Explanatory note:

Annotations

Footnotes

f1

Applies to type 4 containers and type 3 with welded metal liners.