Division 4.2.2.2.9 Removable storage system connector

Original text. Later amendments are not shown.

A removable storage system connector shall be submitted to a number of connection/disconnection cycles equal to three times the number of filling cycles calculated in accordance with section 2.7.6. For each cycle the removable storage system connector shall be pressurised to 1,25 times the nominal working pressure. Subsequently the removable storage system connector shall fulfil the requirements of the external leakage test (section 4.2.5.) when the parts of the removable storage system connector mounted on the vehicle and on the removable storage system are separated and also when connected together.