Division 3.1.2 Verification of the safety concept of section 2.4

Original text. Later amendments are not shown.

The reaction of the safety instrumented system shall, at the discretion of the technical service, be checked under the influence of a failure in any individual unit by applying corresponding output signals to electrical units or mechanical elements in order to simulate the effects of internal faults within the unit.