OpenLegislation

Division 2 In the case of a batch pressure system:

United Kingdom

Original text. Later amendments are not shown.

  1. (a)

    the temperature must be monitored with a permanent thermocouple and it must be plotted against real time;

  2. (b)

    the pressure stage must be monitored with a permanent pressure gauge; pressure must be plotted against real time;

  3. (c)

    the processing time must be shown by time/temperature and time/pressure diagrams.

At least once a year the thermocouple and the pressure gauge must be calibrated.