OpenLegislation

Division 2.4 Spectra (UV/VIS, IR, NMR, MS), molar extinction at relevant wavelengths, optical purity

United Kingdom

Original text. Later amendments are not shown.

The following spectra, including a table of signal characteristics needed for interpretation, shall be determined and reported: ultraviolet/visible (UV/VIS), infrared (IR), nuclear magnetic resonance (NMR) and mass spectra (MS) of purified active substance.

Molar extinction at relevant wavelengths shall be determined and reported (ε in L × mol–1 × cm–1). Relevant wavelengths include all maxima in the UV/visible absorption spectrum, as well as the wavelength range of 290-700 nm.

In the case of active substances which are resolved optical isomers, the optical purity shall be measured and reported.