Division 1 SEASONAL SPACE HEATING ENERGY EFFICIENCY CLASSES
United Kingdom
The seasonal space heating energy efficiency class of a heater, with the exception of low-temperature heat pumps and heat pump space heaters for low-temperature application, shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 1.
The seasonal space heating energy efficiency classes of a low-temperature heat pump and a heat pump space heater for low-temperature application shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 2.
The seasonal space heating energy efficiency of a heater shall be calculated in accordance with points 3 and 4 of Annex VII, for heat pump space heaters, heat pump combination heaters and low-temperature heat pumps under average climate conditions.
Table 1
Seasonal space heating energy efficiency classes of heaters, with the exception of low-temperature heat pumps and heat pump space heaters for low-temperature application
| Seasonal space heating energy efficiency class | Seasonal space heating energy efficiency ηs in % |
|---|---|
| A+++ | ηs ≥ 150 |
| A++ | 125 ≤ ηs < 150 |
| A+ | 98 ≤ ηs < 125 |
| A | 90 ≤ ηs < 98 |
| B | 82 ≤ ηs < 90 |
| C | 75 ≤ ηs < 82 |
| D | 36 ≤ ηs < 75 |
| E | 34 ≤ ηs < 36 |
| F | 30 ≤ ηs < 34 |
| G | ηs < 30 |
Table 2
Seasonal space heating energy efficiency classes of low-temperature heat pumps and heat pump space heaters for low-temperature application
| Seasonal space heating energy efficiency class | Seasonal space heating energy efficiency ηs in % |
|---|---|
| A+++ | ηs ≥ 175 |
| A++ | 150 ≤ ηs < 175 |
| A+ | 123 ≤ ηs < 150 |
| A | 115 ≤ ηs < 123 |
| B | 107 ≤ ηs < 115 |
| C | 100 ≤ ηs < 107 |
| D | 61 ≤ ηs < 100 |
| E | 59 ≤ ηs < 61 |
| F | 55 ≤ ηs < 59 |
| G | ηs < 55 |