Division (b) The active mode coefficient of performance SCOPon for average, colder and warmer climate conditions shall be calculated on the basis of the part load for heating Ph(Tj), the supplementary capacity for heatingsup(Tj) (if applicable), and the bin-specific coefficient of performance COPbin(Tj) or bin-specific primary energy ratio PERbin(Tj), weighted by the bin-hours for which the bin conditions apply, using the following conditions:

United Kingdom

Original text. Later amendments are not shown.

  • the reference design conditions set out in Table 10;

  • the European reference heating season under average, colder and warmer climate conditions set out in Table 12;

  • if applicable, the effects of any degradation of energy efficiency caused by cycling, depending on the type of control of the heating capacity.