Division 5 Water heating energy efficiency of combination heaters
United Kingdom
The water heating energy efficiency ηwh of a combination heater shall be calculated as the ratio between the reference energy Qref and the energy required for its generation under the following conditions:
- (a)
measurements shall be carried out using the load profiles set out in Table 15;
- (b)
measurements shall be carried out using a 24-hour measurement cycle as follows:
-
00:00 to 06:59: no water draw-off;
-
from 07:00: water draw-offs according to the declared load profile;
-
from end of last water draw-off until 24:00: no water draw-off;
-
- (c)
the declared load profile shall be the maximum load profile or the load profile one below the maximum load profile;
- (d)
for heat pump combination heaters, the following additional conditions apply:
-
heat pump combination heaters shall be tested under the conditions set out in Table 9;
-
heat pump combination heaters which use ventilation exhaust air as the heat source shall be tested under the conditions set out in Table 11;
-
- (e)
the annual electricity consumption AEC in kWh in terms of final energy shall be calculated as daily electricity consumption Qelec in kWh in terms of final energy multiplied by 220;
- (f)
the annual fuel consumption AFC in GJ in terms of GCV shall be calculated as daily fuel consumption Qfuel multiplied by 220.