OpenLegislation

Division 7 Technical parameters of water heaters

United Kingdom

Original text. Later amendments are not shown.

The following parameters shall be established for water heaters:

  1. (a)

    the daily electricity consumption Qelec in kWh, rounded to three decimal places;

  2. (b)

    the declared load profile, expressed by the appropriate letter in accordance with Table 3 of this Annex;

  3. (c)

    the sound power level in dB, indoors, rounded to the nearest integer (for heat pump water heaters, if applicable);

in addition, for water heaters using fossil and/or biomass fuels:

  1. (d)

    the daily fuel consumption Qfuel in kWh in terms of GCV, rounded to three decimal places;

in addition, for water heaters for which the value of smart is declared as being ‘1’:

  1. (e)

    the weekly fuel consumption with smart controls Qfuel,week,smart in kWh in terms of GCV, rounded to three decimal places;

  2. (f)

    the weekly electricity consumption with smart controls Qelec,week,smart in kWh, rounded to three decimal places;

  3. (g)

    the weekly fuel consumption without smart controls Qfuel,week in kWh in terms of GCV, rounded to three decimal places;

  4. (h)

    the weekly electricity consumption without smart controls Qelec,week in kWh, rounded to three decimal places;

in addition, for solar water heaters:

  1. (i)

    the collector aperture area Asol in m2, rounded to two decimal places;

  2. (j)

    the zero-loss efficiency η0 , rounded to three decimal places;

  3. (k)

    the first-order coefficient a1 in W/(m2 K), rounded to two decimal places;

  4. (l)

    the second-order coefficient a2 in W/(m2 K2), rounded to three decimal places;

  5. (m)

    the incidence angle modifier IAM, rounded to two decimal places;

  6. (n)

    the pump power consumption solpump in W, rounded to two decimal places;

  7. (o)

    the standby power consumption solstandby in W, rounded to two decimal places;

in addition, for heat pump water heaters:

  1. (p)

    the sound power level LWA in dB, outdoors, rounded to the nearest integer.