    For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using F1designated standards, or using other reliable, accurate and reproducible methods that take into account the generally recognised state-of-the-art methods. They shall meet the conditions and technical parameters set out in points 2 to 5.

  2. 2..

    General conditions for measurements and calculations

    1. (a)

      For the purposes of the measurements set out in points 2 to 5, the indoor ambient temperature shall be set at 20 °C ± 1 °C.

    2. (b)

      For the purposes of the calculations set out in points 3 to 5, consumption of electricity shall be multiplied by a conversion coefficient CC of 2,5.

    3. (c)

      Emissions of nitrogen oxides shall be measured as the sum of nitrogen monoxide and nitrogen dioxide, and expressed in nitrogen dioxide.

    4. (d)

      For heaters equipped with supplementary heaters, the measurement and calculation of rated heat output, seasonal space heating energy efficiency, water heating energy efficiency, sound power level and emissions of nitrogen oxides shall take account of the supplementary heater.

    5. (e)

      Declared values for rated heat output, seasonal space heating energy efficiency, water heating energy efficiency, sound power level and emissions of nitrogen oxides shall be rounded to the nearest integer.

    6. (f)

      Any heat generator designed for a heater, and any heater housing to be equipped with such a heat generator, shall be tested with an appropriate heater housing and heat generator, respectively.

  3. 3..

    Seasonal space heating energy efficiency of boiler space heaters, boiler combination heaters and cogeneration space heaters

    The seasonal space heating energy efficiency ηs shall be calculated as the seasonal space heating energy efficiency in active mode ηson , corrected by contributions accounting for temperature controls, auxiliary electricity consumption, standby heat loss, ignition burner power consumption (if applicable) and, for cogeneration space heaters, corrected by adding the electrical efficiency multiplied by a conversion coefficient CC of 2,5.

  4. 4..

    Seasonal space heating energy efficiency of heat pump space heaters and heat pump combination heaters

    1. (a)

      For establishing the rated coefficient of performance COPrated or rated primary energy ratio PERrated , the sound power level or emissions of nitrogen oxides, the operating conditions shall be the standard rating conditions set out in Table 3 and the same declared capacity for heating shall be used.

    2. (b)

      The active mode coefficient of performance SCOPon or active mode primary energy ratio SPERon shall be calculated on the basis of the part load for heating Ph(Tj), the supplementary capacity for heating sup(Tj) (if applicable) and the bin-specific coefficient of performance COPbin(Tj) or bin-specific primary energy ratio PERbin(Tj), weighted by the bin-hours for which the bin conditions apply, using the following conditions:

      • the reference design conditions set out in Table 4;

      • the European reference heating season under average climate conditions set out in Table 5;

      • if applicable, the effects of any degradation of energy efficiency caused by cycling depending on the type of control of the heating capacity.

    3. (c)

      The reference annual heat demand QH shall be the design load for heating Pdesignh multiplied by the annual equivalent active mode hours HHE of 2 066.

    4. (d)

      The annual energy consumption QHE shall be calculated as the sum of:

      • the ratio of the reference annual heating demand QH and the active mode coefficient of performance SCOPon or active mode primary energy ratio SPERon and

      • the energy consumption for off, thermostat-off, standby, and crankcase heater mode during the heating season.

    5. (e)

      The seasonal coefficient of performance SCOP or seasonal primary energy ratio SPER shall be calculated as the ratio of the reference annual heat demand QH and the annual energy consumption QHE .

    6. (f)

      The seasonal space heating energy efficiency ηs shall be calculated as the seasonal coefficient of performance SCOP divided by the conversion coefficient CC or the seasonal primary energy ratio SPER, corrected by contributions accounting for temperature controls and, for water-/brine-to-water heat pump space heaters and heat pump combination heaters, the electricity consumption of one or more ground water pumps.

  5. 5..

    Water heating energy efficiency of combination heaters

    The water heating energy efficiency ηwh of a combination heater shall be calculated as the ratio between the reference energy Qref of the declared load profile and the energy required for its generation under the following conditions:

    1. (a)

      measurements shall be carried out using the load profiles set out in Table 7;

    2. (b)

      measurements shall be carried out using a 24-hour measurement cycle as follows:

      • 00:00 to 06:59: no water draw-off;

      • from 07:00: water draw-offs according to the declared load profile;

      • from end of last water draw-off until 24:00: no water draw-off;

    3. (c)

      the declared load profile shall be the maximum load profile or the load profile one below the maximum load profile;

    4. (d)

      for heat pump combination heaters, the following additional conditions apply:

      • heat pump combination heaters shall be tested under the conditions set out in Table 3;

      • heat pump combination heaters which use ventilation exhaust air as the heat source shall be tested under the conditions set out in Table 6.

Table 3

Standard rating conditions for heat pump space heaters and heat pump combination heaters

Heat sourceOutdoor heat exchangerIndoor heat exchanger
Inlet dry bulb (wet bulb) temperatureHeat pump space heaters and heat pump combination heaters, except low-temperature heat pumpsLow-temperature heat pumps
Inlet temperatureOutlet temperatureInlet temperatureOutlet temperature
Outdoor air+ 7 °C (+ 6 °C)+ 47 °C+ 55 °C+ 30 °C+ 35 °C
Exhaust air+ 20 °C (+ 12 °C)
Inlet/outlet temperature
Water+ 10 °C/+ 7 °C
Brine0 °C/– 3 °C

Table 4

Reference design conditions for heat pump space heaters and heat pump combination heaters, temperatures in dry bulb air temperature (wet bulb air temperature indicated in brackets)

Reference design temperatureBivalent temperatureOperation limit temperature
Tdesignh Tbiv TOL
– 10 (– 11) °Cmaximum + 2 °Cmaximum – 7 °C

Table 5

European reference heating season under average climate conditions for heat pump space heaters and heat pump combination heaters

binj Tj [°C] Hj [h/annum]
1 to 20– 30 to – 110
21-101
22-925
23-823
24-724
25-627
26-568
27-491
28-389
29-2165
30-1173
310240
321280
332320
343357
354356
365303
376330
387326
398348
409335
4110315
4211215
4312169
4413151
4514105
461574
Total hours:4 910

Table 6

Maximum ventilation exhaust air available [m3/h], at humidity of 5,5 g/m3

Declared load profile XXS XS S M L XL XXL 3XL 4XL
Maximum ventilation exhaust air available1091281281591908701 0212 9438 830

Table 7

Water heating load profiles of combination heaters

h 3XS XXS XS S
Q tap f Tm Q tap f Tm Q tap f Tm Q tap f Tm Tp
kWh l/min°C kWh l/min°C kWh l/min°C kWh l/min°C°C
07:00 0,015 225 0,105 225 0,105 325
07:05 0,015 225
07:15 0,015 225
07:26 0,015 225
07:30 0,015 225 0,105 225 0,525 335 0,105 325
07:45
08:01
08:05
08:15
08:25
08:30 0,105 225 0,105 325
08:45
09:00 0,105 225
09:30 0,105 225 0,105 225 0,105 325
10:00
10:30
11:00
11:30 0,015 225 0,105 225 0,105 325
11:45 0,015 225 0,105 225 0,105 325
12:00 0,015 225 0,105 225
12:30 0,015 225 0,105 225
12:45 0,015 225 0,105 2250,525335 0,315 41055
14:30 0,015 225
15:00 0,015 225
15:30 0,015 225
16:00 0,015 225
16:30
17:00
18:00 0,105 225 0,105 325
18:15 0,105 225 0,105 340
18:30 0,015 225 0,105 225
19:00 0,015 225 0,105 225
19:30 0,015 225 0,105 225
20:00 0,105 225
20:30 1,05 335 0,42 41055
20:45 0,105 225
20:46
21:00 0,105 225
21:15 0,015 225 0,105 225
21:30 0,015 225 0,525 545
21:35 0,015 225 0,105 225
21:45 0,015 225 0,105 225
Qref 0,345 2,1 2,1 2,1
h M L XL
Q tap f Tm Tp Q tap f Tm Tp Q tap f Tm Tp
kWh l/min°C°C kWh l/min°C°C kWh l/min°C°C
07:00 0,105 325 0,105 325 0,105 325
07:05 1,4 640 1,4 640
07:15 1,82 640
07:26 0,105 325
07:30 0,105 325 0,105 325
07:45 0,105 325 4,42 101040
08:01 0,105 325 0,105 325
08:05 3,605 101040
08:15 0,105 325 0,105 325
08:25 0,105 325
08:30 0,105 325 0,105 325 0,105 325
08:45 0,105 325 0,105 325 0,105 325
09:00 0,105 325 0,105 325 0,105 325
09:30 0,105 325 0,105 325 0,105 325
10:00 0,105 325
10:30 0,105 31040 0,105 31040 0,105 31040
11:00 0,105 325
11:30 0,105 325 0,105 325 0,105 325
11:45 0,105 325 0,105 325 0,105 325
12:00
12:30
12:45 0,315 41055 0,315 41055 0,735 41055
14:30 0,105 325 0,105 325 0,105 325
15:00 0,105 325
15:30 0,105 325 0,105 325 0,105 325
16:00 0,105 325
16:30 0,105 325 0,105 325 0,105 325
17:00 0,105 325
18:00 0,105 325 0,105 325 0,105 325
18:15 0,105 340 0,105 340 0,105 340
18:30 0,105 340 0,105 340 0,105 340
19:00 0,105 325 0,105 325 0,105 325
19:30
20:00
20:30 0,735 41055 0,735 41055 0,735 41055
20:45
20:46 4,42 101040
21:00 3,605 101040
21:15 0,105 325 0,105 325
21:30 1,4 640 0,105 325 4,42 101040
21:35
21:45
Qref 5,845 11,655 19,07
h XXL 3XL 4XL
Q tap f Tm Tp Q tap f Tm Tp Q tap f Tm Tp
kWh l/min°C°C kWh l/min°C°C kWh l/min°C°C
07:00 0,105 325 11,2 4840 22,4 9640
07:05
07:15 1,82 640
07:26 0,105 325
07:30
07:45 6,24 161040
08:01 0,105 325 5,04 2425 10,08 4825
08:05
08:15 0,105 325
08:25
08:30 0,105 325
08:45 0,105 325
09:00 0,105 325 1,68 2425 3,36 4825
09:30 0,105 325
10:00 0,105 325
10:30 0,105 31040 0,84 241040 1,68 481040
11:00 0,105 325
11:30 0,105 325
11:45 0,105 325 1,68 2425 3,36 4825
12:00
12:30
12:45 0,735 41055 2,52 321055 5,04 641055
14:30 0,105 325
15:00 0,105 325
15:30 0,105 325 2,52 2425 5,04 4825
16:00 0,105 325
16:30 0,105 325
17:00 0,105 325
18:00 0,105 325
18:15 0,105 340
18:30 0,105 340 3,36 2425 6,72 4825
19:00 0,105 325
19:30
20:00
20:30 0,735 41055 5,88 321055 11,76 641055
20:45
20:46 6,24 161040
21:00
21:15 0,105 325
21:30 6,24 161040 12,04 4840 24,08 9640
21:35
21:45
Qref 24,53 46,76 93,52

Annotations

Textual amendments

F1