OpenLegislation

Commission Delegated Regulation (EU) No 1291/2014 of 16 July 2014 on the conditions for classification, without testing, of wood-based panels under EN 13986 and solid wood panelling and cladding under EN 14915 with regard to their fire protection ability, when used for wall and ceiling covering (Text with EEA relevance)

EU Regulation No 1291/2014 · Adopted 16 July 2014 · Extends to United Kingdom

Original text. legislation.gov.uk does not revise this item, so later amendments are not shown here. Changes made to it are listed under each provision when known.

Commission Delegated Regulation (EU) No 1291/2014

of 16 July 2014

on the conditions for classification, without testing, of wood-based panels under EN 13986 and solid wood panelling and cladding under EN 14915 with regard to their fire protection ability, when used for wall and ceiling covering

(Text with EEA relevance)

THE EUROPEAN COMMISSION,

Having regard to the Treaty on the Functioning of the European Union,

Having regard to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EECf1, and in particular Article 27(5) thereof,

Whereas:

(1)

A system for classifying the performance of construction products, construction works and parts thereof with regard to their resistance to fire was adopted in Commission Decision 2000/367/ECf2. Wood-based panels covered by the harmonised standard EN 13986, as well as solid wood panelling and cladding covered by the harmonised standard EN 14915 are among the construction products to which that Decision applies.

(2)

Tests have shown those products to have a stable and predictable performance concerning fire protection ability when used for wall and ceiling covering provided that the products meet certain conditions regarding the density of the wood and the thickness of the panels, panelling and cladding.

(3)

Wood-based panels covered by the harmonised standard EN 13986 and solid wood panelling and cladding covered by the harmonised standard EN 14915 should therefore be deemed to satisfy the classes of performance for fire protection ability established in Decision 2000/367/EC on those conditions without further testing being required,

HAS ADOPTED THIS REGULATION:

Annotations to the whole text

Footnotes

f1

OJ L 88, 4.4.2011, p. 5.

f2

Commission Decision 2000/367/EC of 3 May 2000 implementing Council Directive 89/106/EEC as regards the classification of the resistance to fire performance of construction products, construction works and parts thereof (OJ L 133, 6.6.2000, p. 26).

Contents

  1. 1Article 1
  2. 2Article 2
  3. Signature
  4. Annex Annex

1

Wood-based panels covered by the harmonised standard EN 13986 and solid wood panelling and cladding covered by the harmonised standard EN 14915 which fulfil the conditions set out in the Annex shall be deemed to satisfy the classes of performance indicated in the Annex without testing, when they are used for wall and ceiling covering.

2

This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.

Signature

C1This Regulation shall be binding in its entirety and directly applicable in all Member States.

Done at Brussels, 16 July 2014.

For the Commission

The President

José Manuel Barroso

Mounted directly on any substrate without an air gap.

Joints with square edges or tongue and groove profile and with the same thickness as the product and without gaps.

Class as set out in Decision 2000/367/EC.

K1 10 for substrates ≥ 300 kg/m3

Brad length minimum 40 mm and spacing maximum 100 mm

Screw length minimum 30 mm and spacing maximum 200 mm

Screw length minimum 30 mm and spacing maximum 150 mm

Screw length minimum 50 mm and spacing maximum 200 mm

Screw length minimum 75 mm and spacing maximum 200 mm

Nail length minimum 60 mm and spacing maximum 600 mm

Nail length minimum 50 mm (in each layer) and spacing maximum 600 mm

The two layers are mounted with the longitudinal direction of the layers perpendicular to each other.

Productf1 EN product standardProduct detailf2 Minimum mean density(kg/m3)Minimum thickness(mm)K Classf3
HardboardEN 13986With and without tongue and groovef4 8009K2 10f5
OSBEN 13986With and without tongue and groovef6 60010K2 10
ParticleboardEN 13986With tongue and groovef7 60010K2 10
ParticleboardEN 13986With and without tongue and groove 60012K2 10
PlywoodEN 13986With and without tongue and groove 45012K2 10
Solid wood panelsEN 13986With and without tongue and groove 45012K2 10
ParticleboardEN 13986With tongue and groovef8 60025K2 30
OSBEN 13986With tongue and groove 60030K2 30
PlywoodEN 13986With tongue and groove 45026K2 30
Solid wood panelsEN 13986With tongue and groove 45026K2 30
Solid wood panelsEN 13986With tongue and groovef9 45053K2 60
Solid wood panelling and claddingEN 14915With tongue and groovef10 45015K2 10
Solid wood panelling and claddingEN 14915With tongue and groove 45027K2 30
Solid wood panelling and claddingEN 14915With tongue and groovef11 4502 × 27f12 K2 60