Mounted in accordance with EN ISO 9239-1, on a substrate of at least Class D-s2, d0 with minimum density of 400 kg/m3 or with an air gap (minimum height 30 mm) underneath.

An interlayer of at least Class Efl and with maximum thickness 3 mm and minimum density of 280 kg/m3 may be included.

Class as set out in Table 2 of the Annex to Decision 2000/147/EC.

Without surface coatings.

Conditioned in accordance with EN 13238 (50 % RH, 23 °C).

Substrate at least Class D-s2, d0.

Applies also to steps of stairs.

Productf1 f2 Product detailf3 Minimum mean densityf4(kg/m3)Minimum overall thickness(mm)End use conditionClass for flooringsf5
Wood flooringSolid wood flooring of pine or spruce

Pine: 480

Spruce: 400

14Without air gap underneathDfl-s1
Wood flooringSolid flooring of beech, oak, pine or spruce

Beech: 700

Oak: 700

Pine: 430

Spruce: 400

20With or without air gap underneathDfl-s1
Wood parquetSolid wood (one layer) parquet of walnut6508Glued to substratef6 Dfl-s1
Wood parquetSolid (one layer) parquet of oak, maple or ash

Ash: 650

Maple: 650

Oak: 720

8Glued to substrate Dfl-s1
Wood parquetMultilayer parquet with oak top layer, at least 3,5 mm55015f7 Without air gap underneathDfl-s1
Wood flooring and parquetSolid wood flooring and parquet not specified above4006AllEfl

Annotations

Footnotes

f1

Mounted in accordance with EN ISO 9239-1, on a substrate of at least Class D-s2, d0 with minimum density of 400 kg/m3 or with an air gap (minimum height 30 mm) underneath.

f2

Applies also to steps of stairs.

f3

Without surface coatings.

f4

Conditioned in accordance with EN 13238 (50 % RH, 23 °C).

f5

Class as set out in Table 2 of the Annex to Decision 2000/147/EC.

f6

Substrate at least Class D-s2, d0.

f7

An interlayer of at least Class Efl and with maximum thickness 3 mm and minimum density of 280 kg/m3 may be included.