Division 5 Specific conditions for seasonal space heating energy efficiency
United Kingdom
- (a)
The seasonal space heating energy efficiency of solid fuel local space heaters is defined as:
ηS = ηS,on – 10% + F(2) + F(3) – F(4) – F(5)
Where:
-
ηS,on is the seasonal space heating energy efficiency in active mode, expressed in %, calculated as set out in point 5(b),
-
F(2) is a correction factor accounting for a positive contribution to the seasonal space heating energy efficiency due to adjusted contributions of controls of indoor heating comfort, the values of which are mutually exclusive, cannot be added to each other, expressed in %,
-
F(3) is a correction factor accounting for a positive contribution to the seasonal space heating energy efficiency due to adjusted contributions of controls for indoor heating comfort the values of which can be added to each other, expressed in %,
-
F(4) is a correction factor accounting for a negative contribution to the seasonal space heating energy efficiency by auxiliary electricity consumption, expressed in %,
-
F(5) is a correction factor accounting for a negative contribution to the seasonal space heating energy efficiency by energy consumption of a permanent pilot flame, expressed in %.
-
- (b)
The seasonal space heating energy efficiency in active mode is calculated as:
ηS,on = ηth,nom
Where:
-
ηth,nom is the useful efficiency at nominal heat output, based on NCV.
-
- (c)
The correction factor F(2) accounting for a positive contribution to the seasonal space heating efficiency due to adjusted contributions of controls for indoor heating comfort, the values of which are mutually exclusive or cannot be added to each other, is calculated as follows:
For solid fuel local space heaters the correction factor F(2) is equal to one of the factors according to Table 2, depending on which control characteristic applies. Only one value can be selected.
Table 2
Correction factor F(2)
If the product is equipped with (only one option may apply): F(2) single stage heat output, no room temperature control 0,0 % two or more manual stages, no temperature control 1,0 % with mechanic thermostat room temperature control 2,0 % with electronic room temperature control 4,0 % with electronic room temperature control plus day timer 6,0 % with electronic room temperature control plus week timer 7,0 % F(2) shall be zero for solid fuel local space heaters not complying with the requirements set out in Annex II, point 2 on emissions where the temperature control is set at the minimum heat output. The heat output in this setting must not be higher than 50 % of the nominal heat output.
- (d)
The correction factor F(3) accounting for a positive contribution to the seasonal space heating efficiency due to adjusted contributions of controls for indoor heating comfort, the values of which can be added to each other, is calculated as follows:
For solid fuel local space heaters the correction factor F(3) is the summation of the values according to Table 3, depending on which control characteristic(s) applies.
Table 3
Correction factor F(3)
If the product is equipped with (multiple options may apply): F(3) room temperature control with presence detection 1,0 % room temperature control with open window detection 1,0 % with distance control option 1,0 % F(3) shall be zero for solid fuel local space heaters not complying with the requirements set out in Annex II, point 2 on emissions where the temperature control is set at the minimum heat output. The heat output in this setting must not be higher than 50 % of the nominal heat output.
- (e)
The auxiliary electricity use correction factor F(4) is calculated as:
This correction factor takes into account the auxiliary electricity use during on-mode and standby-mode operation.
Where:
-
elmax is the electric power consumption at nominal heat output, expressed in kW,
-
elmin is the electric power consumption at minimum heat output, expressed in kW. In case the product does not offer a minimum heat output the value for the electric power consumption at nominal heat output shall be used,
-
elsb is the electric power consumption of the product while in standby mode, expressed in kW,
-
Pnom is the nominal heat output of the product, expressed in kW.
-
- (f)
The correction factor F(5) related to the energy consumption of a permanent pilot flame is calculated as follows:
This correction factor takes into account the permanent pilot flame power requirement.
Where:
-
Ppilot is the pilot flame consumption, expressed in kW;
-
Pnom is the nominal heat output of the product, expressed in kW.
-