Annex V Technical documentation
United Kingdom
For local space heaters, the technical documentation referred to in Article 3(1)(e) and Article 3(2)(e) shall include:
- (a)
the name and address of the supplier;
- (b)
the model identifier;
- (c)
where appropriate, the references of the F1designated standards applied;
- (d)
where the preferred fuel is other woody biomass, non-woody biomass, other fossil fuel or other blend of biomass and fossil fuel as referred to in Table 2, a description of the fuel sufficient for its unambiguous identification and the technical standard or specification of the fuel, including the measured moisture content and the measured ash content, and for other fossil fuel also the measured volatile content of the fuel;
- (e)
where appropriate, the other technical standards and specifications used;
- (f)
the identification and signature of the person empowered to bind the supplier;
- (g)
the information included in Table 2 (for solid fuel local space heaters) and Table 3 (for gaseous/liquid fuel local space heaters), measured and calculated in accordance with Annex VIII;
- (h)
reports of tests undertaken by suppliers or on their behalf, including the name and address of the body that conducted the tests;
- (i)
any specific precautions that shall be taken when the local space heater is assembled, installed or maintained;
- (j)
a list of equivalent models, if applicable.
Table 2
Technical parameters for solid fuel local space heaters
| Model identifier(s): | ||||||||||
| Indirect heating functionality:[yes/no] | ||||||||||
| Direct heat output: …(kW) | ||||||||||
| Indirect heat output: …(kW) | ||||||||||
| Fuel | Preferred fuel (only one): | Other suitable fuel(s): | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Wood logs with moisture content ≤ 25 % | [yes/no] | [yes/no] | ||||||||
| Compressed wood with moisture content < 12 % | [yes/no] | [yes/no] | ||||||||
| Other woody biomass | [yes/no] | [yes/no] | ||||||||
| Non-woody biomass | [yes/no] | [yes/no] | ||||||||
| Anthracite and dry steam coal | [yes/no] | [yes/no] | ||||||||
| Hard coke | [yes/no] | [yes/no] | ||||||||
| Low temperature coke | [yes/no] | [yes/no] | ||||||||
| Bituminous coal | [yes/no] | [yes/no] | ||||||||
| Lignite briquettes | [yes/no] | [yes/no] | ||||||||
| Peat briquettes | [yes/no] | [yes/no] | ||||||||
| Blended fossil fuel briquettes | [yes/no] | [yes/no] | ||||||||
| Other fossil fuel | [yes/no] | [yes/no] | ||||||||
| Blended biomass and fossil fuel briquettes | [yes/no] | [yes/no] | ||||||||
| Other blend of biomass and solid fuel | [yes/no] | [yes/no] | ||||||||
| Characteristics when operating with the preferred fuel | ||||||||||
| Seasonal space heating energy efficiency η s [%]: | ||||||||||
| Energy Efficiency Index (EEI): | ||||||||||
| Item | Symbol | Value | Unit | Item | Symbol | Value | Unit | |||
| Heat output | Useful efficiency (NCV as received) | |||||||||
| Nominal heat output | Pnom | x,x | kW | Useful efficiency at nominal heat output | ηth,nom | x,x | % | |||
| Minimum heat output (indicative) | Pmin | [x,x/N.A.] | kW | Useful efficiency at minimum heat output (indicative) | ηth,min | [x,x/N.A.] | % | |||
| Auxiliary electricity consumption | Type of heat output/room temperature control (select one) | |||||||||
| At nominal heat output | elmax | x,xxx | kW | single stage heat output, no room temperature control | [yes/no] | |||||
| At minimum heat output | elmin | x,xxx | kW | two or more manual stages, no room temperature control | [yes/no] | |||||
| In standby mode | elSB | x,xxx | kW | with mechanic thermostat room temperature control | [yes/no] | |||||
| with electronic room temperature control | [yes/no] | |||||||||
| with electronic room temperature control plus day timer | [yes/no] | |||||||||
| with electronic room temperature control plus week timer | [yes/no] | |||||||||
| Other control options (multiple selections possible) | ||||||||||
| room temperature control, with presence detection | [yes/no] | |||||||||
| room temperature control, with open window detection | [yes/no] | |||||||||
| with distance control option | [yes/no] | |||||||||
| Permanent pilot flame power requirement | ||||||||||
| Pilot flame power requirement (if applicable) | Ppilot | [x,xxx/N.A.] | kW | |||||||
| Contact details | Name and address of the supplier | |||||||||
Table 3
Technical parameters for gaseous/liquid fuel local space heaters
| Model identifier(s): | ||||||||||
| Indirect heating functionality:[yes/no] | ||||||||||
| Direct heat output: …(kW) | ||||||||||
| Indirect heat output: …(kW) | ||||||||||
| Fuel | ||||||||||
| Select fuel type | [gaseous/liquid] | [specify] | ||||||||
| Item | Symbol | Value | Unit | Item | Symbol | Value | Unit | |||
|---|---|---|---|---|---|---|---|---|---|---|
| Heat output | Useful efficiency (NCV) | |||||||||
| Nominal heat output | Pnom | x,x | kW | Useful efficiency at nominal heat output | ηth,nom | x,x | % | |||
| Minimum heat output (indicative) | Pmin | [x,x/N.A.] | kW | Useful efficiency at minimum heat output (indicative) | ηth,min | [x,x/N.A.] | % | |||
| Auxiliary electricity consumption | Type of heat output/room temperature control (select one) | |||||||||
| At nominal heat output | elmax | x,xxx | kW | single stage heat output, no room temperature control | [yes/no] | |||||
| At minimum heat output | elmin | x,xxx | kW | two or more manual stages, no room temperature control | [yes/no] | |||||
| In standby mode | elSB | x,xxx | kW | with mechanic thermostat room temperature control | [yes/no] | |||||
| with electronic room temperature control | [yes/no] | |||||||||
| with electronic room temperature control plus day timer | [yes/no] | |||||||||
| with electronic room temperature control plus week timer | [yes/no] | |||||||||
| Other control options (multiple selections possible) | ||||||||||
| room temperature control, with presence detection | [yes/no] | |||||||||
| room temperature control, with open window detection | [yes/no] | |||||||||
| Permanent pilot flame power requirement | with distance control option | [yes/no] | ||||||||
| Pilot flame power requirement (if applicable) | Ppilot | [x,xxx/N.A.] | kW | |||||||
| Contact details | Name and address of the supplier | |||||||||
Annotations
Textual amendments
- F1
Word in Annex 5 para. (c) substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 5 para. 14(6)(a) (as amended by S.I. 2020/1528, regs. 1(2), 4)
- F2
Words in Annex 5 inserted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 5 para. 14(6)(b) (as amended by S.I. 2020/1528, regs. 1(2), 4)
Footnotes
- f1
-
Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products (OJ L 285, 31.10.2009, p. 10).