Division 1 SOLID FUEL BOILERS

United Kingdom

Original text. Later amendments are not shown.

For solid fuel boilers, the technical documentation referred to in Article 3(1)(e) shall include:

  1. (a)

    the name and address of the supplier;

  2. (b)

    the model identifier;

  3. (c)

    where appropriate, the references of the F1designated standards applied;

  4. (d)

    where the preferred fuel is other woody biomass, non-woody biomass, other fossil fuel or other blend of biomass and fossil fuel as referred to in Table 4, a description of the fuel sufficient for its unambiguous identification and the technical standard or specification of the fuel, including the measured moisture content and the measured ash content, and for other fossil fuel also the measured volatile content of the fuel;

  5. (e)

    where appropriate, the other technical standards and specifications used;

  6. (f)

    the name and signature of the person empowered to bind the supplier;

  7. (g)

    the information included in Table 4, with its technical parameters measured and calculated in accordance with Annex VIII and IX;

  8. (h)

    reports of tests undertaken by suppliers or on their behalf, including the name and address of the body that conducted the test;

  9. (i)

    any specific precautions that must be taken when the solid fuel boiler is assembled, installed or maintained;

  10. (j)

    a list of equivalent models, if applicable.

This information may be merged with the technical documentation provided in accordance with measures under Directive 2009/125/EC of the European Parliament and of the Councilf1 F2or measures listed in paragraph 4 of Schedule 1 to the Ecodesign for Energy-Related Products Regulations 2010.

Table 4

Technical parameters for solid fuel boilers and solid fuel cogeneration boilers

Tank volume = 45 × Pr × (1 – 2,7/Pr ) or 300 litres whichever is higher, with Pr indicated in kW

Tank volume = 20 × Pr with Pr indicated in kW

For the preferred fuel Pn equals Pr

Model identifier
Stoking mode: [Manual: the boiler should be operated with a hot water storage tank of a volume of at least xf2 litre/Automatic: it is recommended that the boiler be operated with a hot water storage tank of a volume of at least xf3 litre]
Condensing boiler: [yes/no]
Solid fuel cogeneration boiler: [yes/no]Combination boiler: [yes/no]
FuelPreferred fuel (only one):Other suitable fuel(s):
Log wood, moisture content ≤ 25 %[yes/no][yes/no]
Chipped wood, moisture content 15-35 %[yes/no][yes/no]
Chipped wood, moisture content > 35 %[yes/no][yes/no]
Compressed wood in the form of pellets or briquettes[yes/no][yes/no]
Sawdust, moisture content ≤ 50 %[yes/no][yes/no]
Other woody biomass[yes/no][yes/no]
Non-woody biomass[yes/no][yes/no]
Bituminous coal[yes/no][yes/no]
Brown coal (including briquettes)[yes/no][yes/no]
Coke[yes/no][yes/no]
Anthracite[yes/no][yes/no]
Blended fossil fuel briquettes[yes/no][yes/no]
Other fossil fuel[yes/no][yes/no]
Blended biomass (30-70 %) and fossil fuel briquettes[yes/no][yes/no]
Other blend of biomass and fossil fuel[yes/no][yes/no]
Characteristics when operating with the preferred fuel:
Seasonal space heating energy efficiency ηs [%]:
Energy efficiency index EEI:
ItemSymbolValueUnitItemSymbolValueUnit
Useful heat outputUseful efficiency
At rated heat outputPn f4x,xkWAt rated heat outputηn x,x%
At [30 %/50 %] of rated heat output, if applicablePp [x,x/N.A.]kWAt [30 %/50 %] of rated heat output, if applicableηp

[x,x/

N.A.]

%
For solid fuel cogeneration boilers: Electrical efficiencyAuxiliary electricity consumption
At rated heat outputelmax x,xxxkW
At rated heat outputηel,n x,x%At [30 %/50 %] of rated heat output, if applicableelmin

[x,xxx/

N.A.]

kW
Of incorporated secondary emission abatement equipment, if applicable

[x,xxx/

N.A.]

kW
In standby modePSB x,xxxkW
Contact detailsName and address of the supplier

Annotations

Textual amendments

F1

Word in Annex 5 s. 1(c) substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 5 para. 15(8)(a); 2020 c. 1, Sch. 5 para. 1(1)

F2

Words in Annex 5 s. 1 inserted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 5 para. 15(8)(b); 2020 c. 1, Sch. 5 para. 1(1)

Footnotes

f1

Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products (OJ L 285, 31.10.2009, p. 10).

f2

Tank volume = 45 × Pr × (1 – 2,7/Pr ) or 300 litres whichever is higher, with Pr indicated in kW

f3

Tank volume = 20 × Pr with Pr indicated in kW

f4

For the preferred fuel Pn equals Pr