Division 1 Specific ecodesign requirements for seasonal space heating energy efficiency
United Kingdom
- (a)
Local space heaters shall comply with the following requirements from 1 January 2018:
- (i)
seasonal space heating energy efficiency of open fronted local space heaters using gaseous or liquid fuel shall not be less than 42 %;
- (ii)
seasonal space heating energy efficiency of closed fronted local space heaters using gaseous or liquid fuel shall not be less than 72 %;
- (iii)
seasonal space heating energy efficiency of electric portable local space heaters shall not be less than 36 %;
- (iv)
seasonal space heating energy efficiency of electric fixed local space heaters with a nominal heat output above 250 W shall not be less than 38 %;
- (v)
seasonal space heating energy efficiency of electric fixed local space heaters with a nominal heat output equal or below 250 W shall not be less than 34 %;
- (vi)
seasonal space heating energy efficiency of electric storage local space heaters shall not be less than 38,5 %;
- (vii)
seasonal space heating energy efficiency of electric underfloor local space heaters shall not be less than 38 %;
- (viii)
seasonal space heating energy efficiency of electric radiant local space heaters shall not be less than 35 %;
- (ix)
seasonal space heating energy efficiency of electric visibly glowing radiant local space heaters with a nominal heat output above 1,2 kW shall not be less than 35 %;
- (x)
seasonal space heating energy efficiency of electric visibly glowing radiant local space heaters with a nominal heat output equal or below 1,2 kW shall not be less than 31 %;
- (xi)
seasonal space heating energy efficiency of luminous local space heaters shall not be less than 85 %;
- (xii)
seasonal space heating energy efficiency of tube local space heaters shall not be less than 74 %.
- (i)